Automatic Calibration of XL3000flex Leak Detector
A closer look at CalMate®, the test leak adapter for automatic calibration
Calibration of leak test equipment prior to use is essential to ensure accurate leak rate readings in a system designed to pass or fail parts. Manufacturing quality control personnel are responsible for verification of the leak test system's performance. By using reference leaks, users receive confirmation of the system's ability to detect and reject defective parts.
The XL3000flex leak detector offers the advantage of automatic calibration using an external test leak and the CalMate adapter.
Designed to fit the external sniffer test leak from INFICON, CalMate automatically calibrates the instrument accurately and without wasting time. This automation makes the job much easier for inexperienced operators, allowing them to obtain accurate results without extensive training or expertise. By simplifying the calibration process, CalMate increases reliability and ensures consistent performance, even for those new to the instrument.
Simple automatic calibration with CalMate
Starting the automatic calibration with CalMate is easy.
Users can easily use the included connection cable. This cable powers CalMate and enables signal exchange between the two devices. By simply inserting the sniffer tip into the CalMate adapter's designated opening, XL3000flex will start calibrating instantly — no further operator action required! XL3000flex needs software version V2.74 or higher to use CalMate.
In addition to automating external calibration, CalMate also verifies the calibration leak, providing swift confirmation that the device is functioning correctly, even without initiating a full calibration. This significantly simplifies the entire calibration process, allowing operators to save valuable time.
Advantages at a glance
- Streamlines the calibration process
- Facilitates calibration for inexperienced operators
- Verifies the test leak
- Ensures consistent performance
- Saves time
Do you have a XL3000flex leak detector and wish to order CalMate?
Refer to the part numbers below or contact the nearest sales representative for assistance!
Product name | Part Number |
---|---|
CalMate (including cable 1m) | 520-250 |
CalMate connection cable 1m | 520-210 |
CalMate connection cable 3m | 520-215 |
Connecting cable CalMate to I/O 1000 | 520-220 |
IO 1000 module | 560-310 |
Do you want to learn more about the importance of an accurate calibration?
Calibrating your test equipment reliably before starting the leak test simplifies job tasks, reduces test times and prevents faulty products from reaching the market.
Read about how to avoid the most common mistakes or watch our webinar on-demand!