Vacuum Feedthroughs & More

Metal Ceramic Connections

Prices & Availability
Metal-Ceramic-Connections-2kV-to-10kV
Drop-in Options

Revolutionize your vacuum gauge experience with us!

Advantages

  • High grade materials allow repeated bakings up to 400° C
  • 2011/65/EU RoHS compliant

Specifications

3 kV
2 kV
5 kV
10 kV
Voltage 1) 3 kV
Insulator Al2O3
Connection
a Fe-Ni
b Fe-Ni
Bakeout temperature°C400
Tightnessmbar•l/s5 x 10-11
Weightg5
1) Based on VDE 0110 for air and surface-leakage in atmosphere on both sides.

    Higher values up to factor two are admissible in pressures <10-4 mbar.

 

Voltage 1) 2 kV
Insulator Al2O3
Connection
a Fe-Co
b stainless steel 
304/1.4301
Bakeout temperature°C400
Tightnessmbar•l/s5 x 10-11
Weightg12
1) Based on VDE 0110 for air and surface-leakage in atmosphere on both sides.

    Higher values up to factor two are admissible in pressures <10-4 mbar.

 

Voltage 1) 5 kV
Insulator Al2O3
Connection
a Fe-Co
b stainless steel 
304/1.4301
Bakeout temperature°C400
Tightnessmbar•l/s5 x 10-11
Weightg25
1) Based on VDE 0110 for air and surface-leakage in atmosphere on both sides.

    Higher values up to factor two are admissible in pressures <10-4 mbar.

 

Voltage 1) 10 kV
Insulator Al2O3
Connection
a Fe-Ni
b stainless steel 
304/1.4301
Bakeout temperature°C400
Tightnessmbar•l/s5 x 10-11
Weightg90
1) Based on VDE 0110 for air and surface-leakage in atmosphere on both sides.

    Higher values up to factor two are admissible in pressures <10-4 mbar.

 

Download full specifications

Order Information

Product
UMK 002 Metal-ceramic
214-161
UMK 006 Metal-ceramic
214-162
UMK 106 Metal-ceramic
214-163
UMK 112 Metal-ceramic
214-164