The INFICON Pirani Standard Gauge (PSG55x) employs like his brothers PCG55x and PSG50x the most advanced digital Pirani technology available. The rugged sensor design combined with the compact size and the variety of features qualifies as the right product for measurement from low to the high vacuum range.
Now available with EtherCAT digital interface!
Ventajas
- Available with Tungsten (PSG550) or Nickel (PSG552) filament or with a fully ceramic coated (PSG554) sensor unit for highly corrosive applications
- Optional display, setpoints and digital interfaces
- Latest EtherCAT protocol Standard ETG.5003.2080 S (R) V1.3.0
- Easy to exchange plug & play sensor element with on-board calibration data - guarantees high reproducibility and low cost of ownership
- Selectable output signal and various plug versions for easy integration
- Mounts in any orientation - provides engineering freedom in tool design
- Diagnostic port on all versions
- Compliance & standards: CE, EN, UL, CSA, RoHS
Aplicaciones típicas
- Fore vacuum pressure measurement
- Safety circuits in vacuum systems
- General vacuum measurement and control from low to the high vacuum range
Especificaciones
PSG550 Tungsten
PSG552 Nickel
PSG554 recubierto de cerámica
Principio de medición | Conductancia térmica según Pirani | |
Rango de medición | Torr mbar | 5×10-5 … 1000 3.8×10-5 … 750 |
Precisión(N2) | ||
5×10-4 … 1×10-3 mbar | % of reading | ±50 |
1×10-3 … 100 mbar | % of reading | ±15 |
100 … 1000 mbar | % of reading | ±50 |
Repetibilidad (N2) | ||
1×10-3 … 100 mbar | % of reading | ±2 |
Orientación de la instalación | cualquier |
Principio de medición | Conductancia térmica según Pirani | |
Rango de medición | Torr mbar | 3.8×10-5 … 750 5×10-5 … 1000 |
Precisión(N2) | ||
5×10-4 … 1×10-3 mbar | % of reading | ±50 |
1×10-3 … 100 mbar | % of reading | ±15 |
100 … 1000 mbar | % of reading | ±50 |
Repetibilidad (N2) | ||
1×10-3 … 100 mbar | % of reading | ±2 |
Orientación de la instalación | cualquier |
Principio de medición | Conductancia térmica según Pirani | |
Rango de medición | Torr mbar | 5×10-5 … 1000 3.8×10-5 … 750 |
Precisión(N2) | ||
5×10-4 … 1×10-3 mbar | % of reading | ±50 |
1×10-3 … 100 mbar | % of reading | ±15 |
100 … 1000 mbar | % of reading | ±50 |
Repetibilidad (N2) | ||
1×10-3 … 100 mbar | % of reading | ±2 |
Orientación de la instalación | cualquier |
Número de parte
Accessories
Spare Parts
PSG550 Tungsten | |
211-001 | Clamping ring DN 10-16 ISO-KF |
350-050 | Power Supply, PxG5xx,G-Cable FCC,1.8m |
PSG552 Nickel | |
211-001 | Clamping ring DN 10-16 ISO-KF |
350-050 | Power Supply, PxG5xx,G-Cable FCC,1.8m |
PSG554 ceramic coated | |
211-001 | Clamping ring DN 10-16 ISO-KF |
211-097 | Centering ring with fine filter DN 16 KF |
350-050 | Power Supply, PxG5xx,G-Cable FCC,1.8m |
PSG552 Nickel | |
211-097 | Centering ring with fine filter DN 16 KF |
PSG550 Tungsten | |
# | |
211-097 | Centering ring with fine filter DN 16 KF |
PSG552 Nickel | |
303-333 | Diagnostic cable 1.9m (P3) |
PSG554 ceramic coated | |
303-333 | Diagnostic cable 1.9m (P3) |
PSG550 Tungsten | |
303-333 | Diagnostic cable 1.9m (P3) |
PSG550 Tungsten | |
355-925 | PSG550 Spare sensor, DN 16 ISO-KF |
355-926 | PSG550 Spare sensor, DN16 ISO-KF, long |
355-927 | PSG550 Spare sensor, DN 16 CF-F |
355-928 | PSG550 Spare sensor, DN 16 CF-R, long |
355-929 | PSG550 Spare sensor, DN 25 ISO-KF |
355-930 | PSG550 Spare sensor, 1/8" NPT |
355-931 | PSG550 Spare sensor, 8-VCR |
355-932 | PSG550 Spare sensor, 4-VCR |
355-933 | PSG550 Spare sensor, 7/16-20 UNF |
355-934 | PSG550 Spare sensor, 29x29mm |
355-935 | PSG550 Spare sensor, 4-VCR / 90° |
PSG552 Nickel | |
355-936 | PSG552 Spare sensor, DN 16 ISO-KF |
355-937 | PSG552 Spare sensor, DN16 ISO-KF, long |
355-938 | PSG552 Spare sensor, DN 16 CF-F |
355-939 | PSG552 Spare sensor, DN 16 CF-R, long |
355-940 | PSG552 Spare sensor, DN 25 ISO-KF |
355-941 | PSG552 Spare sensor, 1/8" NPT |
355-942 | PSG552 Spare sensor, 8-VCR |
355-943 | PSG552 Spare sensor, 4-VCR |
355-944 | PSG552 Spare sensor, 7/16-20 UNF |
355-945 | PSG552 Spare sensor, 29 x 29mm |
355-946 | PSG552 Spare sensor, 4-VCR / 90° |
PSG554 ceramic coated | |
355-947 | PSG554 Spare sensor, DN 16 ISO-KF |
355-948 | PSG554 Spare sensor, DN 16 ISO-KF, long |
355-949 | PSG554 Spare sensor, DN 16 CF-F |
355-950 | PSG554 Spare sensor, DN 16 CF-R, long |
355-951 | PSG554 Spare sensor, DN 25 ISO-KF |
355-952 | PSG554 Spare sensor, 1/8" NPT |
355-953 | PSG554 Spare sensor, 8-VCR |
355-954 | PSG554 Spare sensor, 4-VCR |
355-955 | PSG554 Spare sensor, 7/16-20 UNF |
355-956 | PSG554 Spare sensor, 29x29mm |
355-957 | PSG554 Spare sensor, 4-VCR / 90° |
Número de parte
Descargas
Folletos
Fichas técnicas
PSG55x DE
pdf
•
983,0 KB
•
Alemán
•
Fichas técnicas
PSG55x Datasheet
pdf
•
562,0 KB
•
Inglesa
•
Fichas técnicas
PSG55x JA
pdf
•
1,0 MB
•
Japonés
•
Fichas técnicas
PSG55x KO
pdf
•
975,5 KB
•
Coreano
•
Fichas técnicas
PSG55x ZH
pdf
•
1,0 MB
•
Chino
•
Fichas técnicas
PSG55x
pdf
•
980,3 KB
•
Español
•
Fichas técnicas
Manuales
PSG55x Operating Manual
pdf
•
1,8 MB
•
Inglesa
•
Manual de instrucciones
PxG55x PROFIBUS Communication Protocol
pdf
•
738,1 KB
•
Inglesa
•
Manual de instrucciones
PxG55x DeviceNet Communication Protocol
pdf
•
474,3 KB
•
Inglesa
•
Manual de instrucciones
PxG55x EtherCAT Communication Protocol
pdf
•
493,0 KB
•
Inglesa
•
Manual de instrucciones
PxG55x RS232c RS485c Communication Protocol
pdf
•
177,9 KB
•
Inglesa
•
Manual de instrucciones
TIRB72E1_PxG55x_Communication Protocol PROFINET
pdf
•
1,6 MB
•
Inglesa
•
Manual de instrucciones
Archivos 3D
MPSG55x_Plug_RS485_UNF.stp
stp
•
1,9 MB
•
Archivos 3D
PxG550_9DSub_16K_long
zip
•
297,4 KB
•
Archivos 3D
PxG55x_15DSub_16CF
zip
•
280,5 KB
•
Archivos 3D
PxG55x_15DSub_16KF
zip
•
274,8 KB
•
Archivos 3D
PxG55x_15DSub_4VCR
zip
•
283,7 KB
•
Archivos 3D
PxG55x_15DSub_DNet_16CF
zip
•
313,7 KB
•
Archivos 3D
PxG55x_15DSub_DNet_16KF
zip
•
308,2 KB
•
Archivos 3D
PxG55x_15DSub_DNet_4VCR
zip
•
314,6 KB
•
Archivos 3D
PxG55x_15DSub_PBus_16CF
zip
•
330,5 KB
•
Archivos 3D
PxG55x_15DSub_PBus_16KF
zip
•
324,9 KB
•
Archivos 3D
PxG55x_15DSub_PBus_4VCR
zip
•
331,4 KB
•
Archivos 3D
PxG55x_9DSub_16CF
zip
•
256,7 KB
•
Archivos 3D
PxG55x_9DSub_16KF
zip
•
251,2 KB
•
Archivos 3D
PxG55x_9DSub_25KF
zip
•
251,5 KB
•
Archivos 3D
PxG55x_9DSub_29x29
zip
•
214,5 KB
•
Archivos 3D
PxG55x_9DSub_4VCR
zip
•
257,5 KB
•
Archivos 3D
PxG55x_9DSub_4VCR_90
zip
•
214,3 KB
•
Archivos 3D
PxG55x_9DSub_8VCR
zip
•
255,8 KB
•
Archivos 3D
PxG55x_9DSub_DNet_16CF
zip
•
287,8 KB
•
Archivos 3D
PxG55x_9DSub_DNet_16KF
zip
•
282,3 KB
•
Archivos 3D
PxG55x_9DSub_DNet_25KF
zip
•
298,5 KB
•
Archivos 3D
PxG55x_9DSub_DNet_4VCR
stp
•
2,1 MB
•
Archivos 3D
PxG55x_9DSub_EtherCAT_16CF
zip
•
349,0 KB
•
Archivos 3D
PxG55x_9DSub_EtherCAT_16KF
zip
•
344,2 KB
•
Archivos 3D