$ $ Electronic Data Sheet $ Inficon HPG 400-SD Float Configuration $ [File] DescText = "Inficon HPG400-SD EDS File"; CreateDate = 11-14-2001; CreateTime = 16:41:20; ModDate = 11-24-2004; ModTime = 17:15:20; Revision = 1.2; [Device] VendCode = 633; $ Vendor Code ProdType = 28; $ Product Type ProdCode = 10; $ Product Code MajRev = 1; $ Major Rev MinRev = 3; $ Minor Rev VendName = "INFICON AG"; ProdTypeStr = "Vacuum/Pressure Gauge"; ProdName = "HPG400-SD"; Catalog = ""; [IO_Info] Default = 0X0001; PollInfo = 0X0001, $ only Poll 2, $ Default: Input 2 0; $ No Output $ Input Assemblies Input1 = 2, 0 , 0x0001,"Input Assembly 1", 6, "20 4 24 1 30 3", "INT Pressure"; Input2 = 3, 0 , 0x0001,"Input Assembly 2", 6, "20 4 24 2 30 3", "Exception Status, INT Pressure"; Input3 = 4, 0 , 0x0001,"Input Assembly 4", 6, "20 4 24 4 30 3", "REAL Pressure"; Input4 = 5, 0 , 0x0001,"Input Assembly 5", 6, "20 4 24 5 30 3", "Exception Status, REAL Pressure"; Input5 = 1, 0 , 0x0001,"Input Assembly 8", 6, "20 4 24 8 30 3", "Exception Status"; Input6 = 4, 0 , 0x0001,"Input Assembly 9", 6, "20 4 24 9 30 3", "Active Sensor No., INT Pressure"; Input7 = 5, 0 , 0x0001,"Input Assembly 10", 6, "20 4 24 A 30 3", "Exception Status, Active Sensor No., INT Pressure"; Input8 = 6, 0 , 0x0001,"Input Assembly 12", 6, "20 4 24 C 30 3", "Active Sensor No., REAL Pressure"; Input9 = 7, 0 , 0x0001,"Input Assembly 13", 6, "20 4 24 D 30 3", "Exception Status, Active Sensor No., REAL Pressure"; [ParamClass] MaxInst=36; Descriptor=0; CfgAssembly=0; [Params] $ **************************************************************************** $ * Parameter Instance #1: Active Value $ **************************************************************************** Param1= 0, $ parameter value slot 6, "20 31 24 00 30 5E", $ link size and path 0x0030, $ descriptor (RO, Mon) 11, 4, $ REAL, 4 bytes "Active Value", $ parameter name "", $ units string "", 0,100000, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #2: Pressure Unit $ **************************************************************************** Param2= 0, $ parameter value slot 6, "20 31 24 01 30 04", $ link size and path 0x0020, $ descriptor (Mon) 2, 2, $ Unsigned, 2 bytes "Pressure Unit", $ parameter name "", $ units string "COUNTS=4097; TORR=4865; mBAR=4872, PASCAL=4873", 4097, 4873, 4097, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #3: Data Type $ **************************************************************************** Param3= 0, $ parameter value slot 6, "20 31 24 01 30 3", $ link size and path 0x0022, $ descriptor (Mon, Enum) 8, 1, $ USINT, 1 byte "Data Type", $ parameter name "", $ units string "INT=195(0xC3), REAL=202(0xCA)", 195, 202, 195, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #4: Active Instance $ **************************************************************************** Param4= 0, $ parameter value slot 6, "20 31 24 00 30 5F", $ link size and path 0x0032, $ descriptor (RO, Mon) 2, 2, $ Unsigned, 2 bytes "Active Instance", $ parameter name "", $ units string "", 1,2, 1, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #5: Device State $ **************************************************************************** Param5= 0, $ parameter value slot 6, "20 30 24 01 30 0B", $ link size and path 0x0032, 8, 1, $ descriptor (RO, Mon), byte "Device State", $ parameter name "", "", $ units string 000, 0x7, 000, $ min, max, default 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #6: Exception Status $ **************************************************************************** Param6= 0, $ parameter value slot 6, "20 30 24 01 30 0C", $ link size and path 0x0032, $ descriptor Enum, RO, Mon 24, 1, $ Unsigned, 2 bytes "Exception Status", $ parameter name "", $ units string "", 0, 0xFF, 000, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, $ scaling links and 0; $ precision $ **************************************************************************** $ * Parameter Instance #7: IO Assembly $ **************************************************************************** Param7= 0, $ parameter value slot 6, "20 5 24 02 30 64", $ link size and path 0x0022, $ descriptor (Mon) 8, 1, $ USINT, 1 Bytes "Poll IO Assembly", $ parameter name "", $ units string "Changes take effect only after a Reset of the Device", 1, 13, 2, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ ****************************************************************************** $ ****************************** PIRANI **************************************** $ ****************************************************************************** $ **************************************************************************** $ * Parameter Instance #8: Value Pirani $ **************************************************************************** Param8= 0, $ parameter value slot 6, "20 31 24 01 30 06", $ link size and path 0x0030, $ descriptor (RO, Mon) 11, 4, $ Real, 4 bytes "S1 Value", $ parameter name "", $ units string "", 0,100000, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #9: Reading Valid Pirani $ **************************************************************************** Param9= 0, $ parameter value slot 6, "20 31 24 01 30 05", $ link size and path 0x0030, $ descriptor (RO, Mon) 4, 1, $ Bool, 1 byte "S1 Reading Valid", $ parameter name "", $ units string "", 0, 1, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #10: Pirani Alarm $ **************************************************************************** Param10= 0, 6, "20 31 24 01 30 5F", 0x0032, 1, 2, "S1 Alarm", "", "", 000, 0xFFFF, 000, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #11: Pirani Warning $ **************************************************************************** Param11= 0, 6, "20 31 24 01 30 5E", 0x0032, 1, 2, "S1 Warning", "", "", 000, 0xFFFF, 000, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #12: Pirani Status Extension $ **************************************************************************** Param12= 0, 6, "20 31 24 01 30 60", 0x0032, 24, 1, "S1 XStatus", "", "", 000, 0xFF, 000, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #13: Safe State Pirani $ **************************************************************************** Param13= 0, $ parameter value slot 6, "20 31 24 01 30 19", $ link size and path 0x0022, $ descriptor ( Mon, Enum) 8, 1, $ USINT "S1 Safe State", $ parameter name "", $ units string "", 0,3, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #14: Safe Value Pirani $ **************************************************************************** Param14= 0, $ parameter value slot 6, "20 31 24 01 30 1A", $ link size and path 0x0020, $ descriptor (Mon) 11, 4, $ Real, 4 bytes "S1 Safe Value", $ parameter name "", $ units string "", 0, 300000000000000000000000000000000000000, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #15: Full Scale Pirani $ **************************************************************************** Param15= 0, $ parameter value slot 6, "20 31 24 01 30 0A", $ link size and path 0x0030, $ descriptor (RO, Mon) 11, 4, $ Real, 4 bytes "S1 Full Scale", $ parameter name "", $ units string "", 0,100000, 30333, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #16: Overrange $ **************************************************************************** Param16= 0, $ parameter value slot 6, "20 31 24 01 30 20", $ link size and path 0x0030, $ descriptor (RO, Mon) 11, 4, $ REAL, 4 bytes "S1 Overrange", $ parameter name "", $ units string "", 0,100000 , 30333, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #17: Underrange Pirani $ **************************************************************************** Param17= 0, $ parameter value slot 6, "20 31 24 01 30 21", $ link size and path 0x0030, $ descriptor (RO, Mon) 11, 4, $ Real, 4 bytes "S1 Underrange", $ parameter name "", $ units string "", 0,100000,27000, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8 ; $ scaling links and precision $ ****************************************************************************** $ ******************************** IONI **************************************** $ ****************************************************************************** $ **************************************************************************** $ * Parameter Instance #18: Value IONI $ **************************************************************************** Param18= 0, $ parameter value slot 6, "20 31 24 02 30 06", $ link size and path 0x0030, $ descriptor (RO, Mon) 11, 4, $ Real, 4 bytes "S2 Value", $ parameter name "", $ units string "", 0, 100000, 24333, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #19: Reading Valid IONI $ **************************************************************************** Param19= 0, $ parameter value slot 6, "20 31 24 02 30 05", $ link size and path 0x0030, $ descriptor (RO, Mon) 4, 1, $ Bool, 1 byte "S2 Reading Valid", $ parameter name "", $ units string "", 0, 1, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #20: IONI Alarm $ **************************************************************************** Param20= 0, 6, "20 31 24 02 30 5F", 0x0032, 1, 2, "S2 Alarm", "", "", 000, 0xFFFF, 000, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #21: IONI Warning $ **************************************************************************** Param21= 0, 6, "20 31 24 02 30 5E", 0x0032, 1, 2, "S2 Warning", "", "", 000, 0xFFFF, 000, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #22: IONI Status Extension $ **************************************************************************** Param22= 0, 6, "20 31 24 02 30 60", 0x0032, 24, 1, "S2 XStatus", "", "", 000, 0xFF, 000, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #23: Safe State IONI $ **************************************************************************** Param23= 0, $ parameter value slot 6, "20 31 24 02 30 19", $ link size and path 0x0022, $ descriptor ( Mon, Enum) 8, 1, $ USINT "S2 Safe State", $ parameter name "", $ units string "", 0,3, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #24: Safe Value IONI $ **************************************************************************** Param24= 0, $ parameter value slot 6, "20 31 24 02 30 1A", $ link size and path 0x0020, $ descriptor (Mon) 11, 4, $ Real, 4 bytes "S2 Safe Value", $ parameter name "", $ units string "", 0, 300000000000000000000000000000000000000, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #25: Full Scale IONI $ **************************************************************************** Param25= 0, $ parameter value slot 6, "20 31 24 02 30 0A", $ link size and path 0x0030, $ descriptor (RO, Mon) 11, 4, $ Real, 4 bytes "S2 Full Scale", $ parameter name "", $ units string "", 0,100000, 24333, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #26: Overrange IONI $ **************************************************************************** Param26= 0, $ parameter value slot 6, "20 31 24 02 30 20", $ link size and path 0x0030, $ descriptor (RO, Mon) 11, 4, $ REAL, 4 bytes "S2 Overrange", $ parameter name "", $ units string "", 0,100000 , 24333, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #27: Underrange IONI $ **************************************************************************** Param27= 0, $ parameter value slot 6, "20 31 24 02 30 21", $ link size and path 0x0030, $ descriptor (RO, Mon) 11, 4, $ Real, 4 bytes "S2 Underrange", $ parameter name "", $ units string "", 0,100000, 8333, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 6 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #28: Exception Alarm Enable $ **************************************************************************** Param28= 0, 6, "20 30 24 01 30 0F", 0x0022, 4, 1, "Enable Alarm", "", "", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #29: Exception Warning Enable $ **************************************************************************** Param29= 0, 6, "20 30 24 01 30 10", 0x0022, 4, 1, "Enable Warning", "", "", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #30: Interlock A Value $ **************************************************************************** Param30= 0, 6, "20 31 24 15 30 06", 0x0030, 11, 4, "Interlock A", "", "The pressure value is displayed in the actual unit", 0.000, 10000, 0.0, 1, 1, 1, 0, 0, 0, 0, 0, 8; $ **************************************************************************** $ * Parameter Instance #31: Interlock A Status $ **************************************************************************** Param31= 0, 6, "20 31 24 15 30 07", 0x0032, 24, 1, "InterlockA State", "", "", 0, 0XFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #32: Interlock B Value $ **************************************************************************** Param32= 0, 6, "20 31 24 16 30 06", 0x0030, 11, 4, "Interlock B", "", "The pressure value is displayed in the actual unit", 0.000, 10000, 0.0005, 1, 1, 1, 0, 0, 0, 0, 0, 8; $ **************************************************************************** $ * Parameter Instance #33: Interlock B Status $ **************************************************************************** Param33= 0, 6, "20 31 24 16 30 07", 0x0032, 24, 1, "InterlockB State", "", "", 0, 0XFF, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #34: Emission Status $ **************************************************************************** Param34= 0, 6, "20 31 24 02 30 5d", 0x0020, 4, 1, "Emission Status", "", "", 0, 1, 0, 1, 1, 1, 0, 0, 0, 0, 0, 0; $ **************************************************************************** $ * Parameter Instance #35: Sensitivity $ **************************************************************************** Param35= 0, $ parameter value slot 6, "20 30 24 01 30 65", $ link size and path 0x0030, $ descriptor (Mon) 8, 1, $ Real, 4 bytes "Sensitivity", $ parameter name "", $ units string "", 0, 255, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #36: IONI Emmission On Threshold Pressure $ **************************************************************************** Param36= 0, $ parameter value slot 6, "20 30 24 01 30 66", $ link size and path 0x0030, $ descriptor (Mon) 11, 4, $ Real, 4 bytes "Threshold Pressure", $ parameter name "", $ units string "", 0, 100, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 8; $ scaling links and precision [EnumPar] $ **************************************************************************** $ * Parameter Instance #3: Data Type $ **************************************************************************** Param3= "16-bit Signed Integer","res","res","res","res","res","res", "32-bit Floating Point Value"; $ **************************************************************************** $ * Parameter Instance #4: Active Instance $ **************************************************************************** Param4= "Heat Transfer Gauge", "Hot Cathode Ion Gauge"; $ **************************************************************************** $ * Parameter Instance #5: Device State $ **************************************************************************** Param5= "Undefined", "Self Testing", "Idle", "Self Test Exception", "Executing", "Abort", "Critical fault", "res."; $ **************************************************************************** $ * Parameter Instance #6: Exception Status $ **************************************************************************** Param6= "Alarm Device Common", "Alarm Device Specific", "Alarm Manufacterer Specific", "reserved", "Warning Device Common", "Warning Device Specific", "Warning Device Common", "Enhanced Mode"; $ **************************************************************************** $ * Parameter Instance #7 IO Assembly $ **************************************************************************** Param7= "IO Assembly 1", "IO Assembly 2", "not supported", "IO Assembly 4", "IO Assembly 5", "not supported", "not supported", "IO Assembly 8", "IO Assembly 9", "IO Assembly 10", "not supported", "IO Assembly 12", "IO Assembly 13"; $ **************************************************************************** $ * Parameter Instance #10: Pirani Alarm $ **************************************************************************** Param10= "Sensor Element Failure", "res.", "res.", "res.", "res.", "res.", "res.", "res.", "res.", "Electronics Failure", "Over Temp. of Electronics", "res.", "res.", "res.", "res.", "res."; $ **************************************************************************** $ * Parameter Instance #11: Pirani Warning $ **************************************************************************** Param11= "res.", "res.", "res.", "res.", "res.", "res.", "res.", "res.", "res.", "Electronics Warning", "High Temp. Warning", "res.", "res.", "res.", "res.", "res."; $ **************************************************************************** $ * Parameter Instance #12: Pirani Status Extension $ **************************************************************************** Param12= "Reading Invalid", "Overrange Exceeded", "Underrange Exceeded", "res.", "res.", "res.", "res.", "res."; $ **************************************************************************** $ * Parameter Instance #13: Safe State Pirani $ **************************************************************************** Param13= "Zero", "Full Scale", "Hold Last Value", "Use Safe Value"; $ **************************************************************************** $ * Parameter Instance #20: IONI Alarm $ **************************************************************************** Param20= "Filament 1 Alarm", "res.", "res.", "res.", "res.", "res.", "res.", "res.", "C/E Ratio", "Electronics Failure", "Over Temp. of Electronics", "Overpressure", "Environment Failure", "res.", "res.", "res."; $ **************************************************************************** $ * Parameter Instance #21: IONI Warning $ **************************************************************************** Param21= "Filament 1 Warning", "res.", "res.", "res.", "res.", "res.", "res.", "res.", "C/E Ratio", "Electronics Warning", "res.", "p too high for Degas", "Sensor Warning", "res.", "res.", "res."; $ **************************************************************************** $ * Parameter Instance #22: IONI Status Extension $ **************************************************************************** Param22= "Reading Invalid", "Overrange Exceeded", "Underrange Exceeded", "res.", "res.", "res.", "res.", "res."; $ **************************************************************************** $ * Parameter Instance #23: Safe State IONI $ **************************************************************************** Param23= "Zero", "Full Scale", "Hold Last Value", "Use Safe Value"; $ **************************************************************************** $ * Parameter Instance #28: Exception Alarm Enable $ **************************************************************************** Param28= "Disable", "Enable"; $ **************************************************************************** $ * Parameter Instance #29: Exception Warning Enable $ **************************************************************************** Param29= "Disable", "Enable"; $ **************************************************************************** $ * Parameter Instance #31: Interlock A Status $ **************************************************************************** Param31= "High Alarm Exception", "Low Alarm Exception", "High warning Exception", "Low Warning Exception", "res", "res", "res", "res"; $ **************************************************************************** $ * Parameter Instance #33: Interlock A Status $ **************************************************************************** Param33= "High Alarm Exception", "Low Alarm Exception", "High warning Exception", "Low Warning Exception", "res", "res", "res", "res"; [Groups] Group1= "Device Supervisor", 4, 5, 6, 28, 29; Group2= "Analog Sensor 1", 12, 8, 2, 3, 9, 10, 11, 12, 13, 14, 15, 16, 17; Group3= "Analog Sensor 2", 12, 18, 2, 3, 19, 20, 21, 22, 23, 24, 25, 26, 27; Group4= "Interlock A", 2, 30, 31; Group5= "Interlock B", 2, 32, 33; Group6= "Debug", 21, 1, 4, 2, 3, 5, 8, 9, 18, 19, 34, 45, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44; Group7= "IO Data",1, 7; $ End of INFICON BPG400-SD EDS File