$
$ Electronic Data Sheet for the TTR211S-D
$ Leybold Vakuum GmbH
$

[File]
     DescText    = " Leybold Vakuum TTR21XS-D EDS File - TTR2";
     CreateDate  = 08-08-97;
     CreateTime  = 12:00:00;
     ModDate     = 10-29-2003;
     ModTime     = 12:00:00;
     Revision    = 1.02;
[Device]
     VendCode    = 144;                                $ Vendor Code
     VendName    = "Leybold Vakuum";
     ProdType    = 0;                                  $ Product Type
     ProdTypeStr = "Generic";
     ProdCode    = 2;                                  $ Product Code
     MajRev      = 1;                                  $ Major Rev
     MinRev      = 0;                                  $ Minor Rev
     ProdName    = "TTR211S-D";
     Catalog     = "89651";

[IO_Info]
     Default     = 0x0001;				$ Poll, BitStrobe, COS
     PollInfo    = 0x0007, 
     		   1, 					$ Default: Producing 3
     		   1;					$ Default: Consuming 1

     StrobeInfo  = 0x0007, 
     		   3, 					$ Default: Producing 5
     		   1;					$ Default: Consuming 1

     COSInfo     = 0X0007, 
     		   1,					$ Default: Producing 3 
     		   1;					$ Default: Consuming 1

$ Input Assemblies

     Input1      = 6,                                  $ bytes to be transfered
                   0,                                  $ significant bits
                   0x0007,                             $ Compatible I/O type mask
                   "Input Assembly 3",
                   6, "20 04 24 03 30 03",             $ Connection Path Size/Path
                   "Status, Except, Press";            $ Help String

     Input2      = 14,                                 $ bytes to be transfered
                   0,                                  $ significant bits
                   0x0007,                             $ Compatible I/O type mask
                   "Input Assembly 4",
                   6, "20 04 24 04 30 03",             $ Connection Path Size/Path
                   "Status, Except, Press, TripPoint"; $ Help String
                   
     Input3      = 4,                                  $ bytes to be transfered
                   0,                                  $ significant bits
                   0x0007,                             $ Compatible I/O type mask
                   "Input Assembly 5",
                   6, "20 04 24 05 30 03",             $ Connection Path Size/Path
                   "Pressure";		               $ Help String
                   
     Input4      = 1,                                  $ bytes to be transfered
                   0,                                  $ significant bits
                   0x0007,                             $ Compatible I/O type mask
                   "Input Assembly 6",
                   6, "20 04 24 06 30 03",             $ Connection Path Size/Path
                   "Exception";         	       $ Help String
                   

     Output1      = 1,                                  $ bytes to be transfered
                    0,                                  $ significant bits
                    0x0007,                             $ Compatible I/O type mask
                    "Output Assembly 1",
                    6, "20 04 24 01 30 03",             $ Connection Path Size/Path
                    "Trip Source";             	        $ Help String
                    
     Output2      = 9,                                  $ bytes to be transfered
                    0,                                  $ significant bits
                    0x0007,                             $ Compatible I/O type mask
                    "Output Assembly 2",
                    6, "20 04 24 02 30 03",             $ Connection Path Size/Path
                    "Trip Source, Trip Point"; 	        $ Help String
                      
                   

[ParamClass]
	MaxInst=11;
	Descriptor=0;
	CfgAssembly=0;

[Params]

$ SENSOR PRESSURE OBJECT

$ ****************************************************************************
$ * Parameter Instance #1:  Sensor State
$ ****************************************************************************
        Param1=
                0,                      $ parameter value slot
                6, "20 67 24 01 30 03", $ link size and path
                0x0032,                 $ descriptor (RO, Mon, Enum)
                0xC1, 1,                $ BOOL, 1 bytes
                "Sensor State",         $ parameter name
                "",                     $ units string
                "Gauge ON == Normal Operation ",
                0, 0x1, 0,              $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision


$ TRANSFORM PRESSURE OBJECT

$ ****************************************************************************
$ * Parameter Instance #2:  Pressure Value
$ ****************************************************************************
        Param2=
                0,                      $ parameter value slot
                6, "20 68 24 01 30 01", $ link size and path
                0x0030,                 $ descriptor (RO, Mon, Enum)
                0xca, 4,                $ Real, 1 bytes
                "Pressure Value",       $ parameter name
                "",                     $ units string
                "The pressure value is displayed in the actual unit mbar or Torr",
                0.0005, 1000, 0.0005,   $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 4;          $ scaling links and precision


$ ****************************************************************************
$ * Parameter Instance #3:  Pressure Unit
$ ****************************************************************************
        Param3=
                0,                      $ parameter value slot
                6, "20 68 24 01 30 03", $ link size and path
                0x0022,                 $ descriptor (Mon, Enum)
                0xc6, 1,                $ USINT, 1 bytes
                "Pressure Unit",        $ parameter name
                "",                     $ units string
                "mbar , Torr , Pascal",
                0,2,0,                  $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision


$ DISCRETE OUTPUT POINT

$ ****************************************************************************
$ * Parameter Instance #4:  TP State
$ ****************************************************************************
        Param4=
                0,                      $ parameter value slot
                6, "20 69 24 01 30 03", $ link size and path
                0x0032,                 $ descriptor (Mon, Enum)
                0xC1, 1,                $ BOOL, 1 bytes
                "Trip Point State",     $ parameter name
                "",                     $ units string
                "0 relais deactivated, 1 relais activated ",
                0, 0x1, 0,              $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision


$ ****************************************************************************
$ * Parameter Instance #5:  TP
$ ****************************************************************************
        Param5=
                0,                      $ parameter value slot
                6, "20 69 24 01 30 64", $ link size and path
                0x0020,                 $ descriptor (RO, Mon, Enum)
                0xca, 4,                $ Real, 1 bytes
                "Trip Point",           $ parameter name
                "",     $ units string
                "Only active if Trip Point Control Source == DeviceNet",
                0.0005, 1000, 0.0005,   $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 4;          $ scaling links and precision
$ ****************************************************************************
$ * Parameter Instance #6:  TP Hysteresis
$ ****************************************************************************
        Param6=
                0,                      $ parameter value slot
                6, "20 69 24 01 30 66", $ link size and path
                0x0020,                 $ descriptor ( Mon, Enum)
                0xca, 4,                $ Real, 1 bytes
                "Trip Point Hysteresis",         $ parameter name
                "%",                    $ units string
                "Hysteresis in Percent",
                0.1, 100, 0.1,          $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 4;          $ scaling links and precision
$ ****************************************************************************
$ * Parameter Instance #7:  TP Upper Value
$ ****************************************************************************
        Param7=
                0,                      $ parameter value slot
                6, "20 69 24 01 30 67", $ link size and path
                0x0020,                 $ descriptor (RO, Mon, Enum)
                0xca, 4,                $ Real, 1 bytes
                "Trip Point Upper Value",         $ parameter name
                "",                     $ units string
                "Only active if Trip Point Control Source == DeviceNet",
                0.0005, 1000, 0.0005  , $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 4;          $ scaling links and precision
$ ****************************************************************************
$ * Parameter Instance #8:  TP Lower Value
$ ****************************************************************************
        Param8=
                0,                      $ parameter value slot
                6, "20 69 24 01 30 68", $ link size and path
                0x0020,                 $ descriptor ( Mon, Enum)
                0xca, 4,                $ Real, 1 bytes
                "Trip Point Lower Value",         $ parameter name
                "",                  $ units string
                "Only active if Trip Point Control Source == DeviceNet",
                0.0005, 1000, 0.0005  , $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 4;          $ scaling links and precision
$ ****************************************************************************
$ * Parameter Instance #9:  TP Control Source
$ ****************************************************************************
        Param9=
                0,                      $ parameter value slot
                6, "20 69 24 01 30 69", $ link size and path
                0x0022,                 $ descriptor (Mon, Enum)
                0xC1, 1,                $ BOOL, 1 bytes
                "Trip Point Control Source",         $ parameter name
                "",                     $ units string
                "You can define whether the trip point is installed by DeviceNet or by the potentiometer of the ITR100-D",
                0, 0x1, 0,              $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision

$ ANALOG OUTPUT POINT

$ ****************************************************************************
$ * Parameter Instance #10:  Analog Output Mode
$ ****************************************************************************
        Param10=
                0,                      $ parameter value slot
                6, "20 70 24 01 30 65", $ link size and path
                0x0032,                 $ descriptor (Mon, Enum)
                0xc6, 1,                $ USINT, 1 bytes
                "Analog Output Mode",   $ parameter name
                "",                     $ units string
                "Log: Ua=(log(p/mbar)*1.286 +6.143 "   ,
                0, 0, 0,                $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision

[Groups]
$      Group1="SPO",1;
$      Group2="TPO",2,3;
$      Group3="DOP",4,5,6,7,8,9;
$      Group4="AOP",10;


[EnumPar]
$ ****************************************************************************
$ * Parameter Instance #1:  Sensor State
$ ****************************************************************************
        Param1=
                "FAIL",
                "ON";



$ ****************************************************************************
$ * Parameter Instance #3:  Pressure Unit
$ ****************************************************************************
        Param3=
                "mbar",
                "torr",
                "Pascal";


$ ****************************************************************************
$ * Parameter Instance #4:  TP State
$ ****************************************************************************
        Param4=
                "OFF",
                "ON";




$ ****************************************************************************
$ * Parameter Instance #9:  TP Control Source
$ ****************************************************************************
        Param9=
                "Potentiometer",
                "DeviceNet";


$ ****************************************************************************
$ * Parameter Instance #10:  Analog Output Mode
$ ****************************************************************************
        Param10=
                "log";