$
$ Electronic Data Sheet for the PEG100-SD
$
$
[File]
DescText = " Leybold Vakuum PEG100-D EDS File ";
CreateDate = 08-08-97;
CreateTime = 12:00:00;
ModDate = 01-20-2005;
ModTime = 12:00:00;
Revision = 1.02;
[Device]
VendCode = 144; $ Vendor Code
VendName = "Leybold Vakuum";
ProdType = 0; $ Product Type
ProdTypeStr = "Generic";
ProdCode = 3; $ Product Code
MajRev = 1; $ Major Rev
MinRev = 0; $ Minor Rev
ProdName = "PEG100-D";
Catalog = "351-003";
[IO_Info]
Default = 0x000F; $ Poll, BitStrobe, COS, Cyclic
PollInfo = 0x000F,
1, $ Default: Producing 2
1; $ Default: Consuming 1
StrobeInfo = 0x000F,
1, $ Default: Producing 2
1; $ Default: Consuming 1
COSInfo = 0x000F,
1, $ Default: Producing 2
1; $ Default: Consuming 1
CyclicInfo = 0x000F,
1, $ Default: Producing 2
1; $ Default: Consuming 1
$ Input Assemblies
Input1 = 6, $ bytes to be transfered
0, $ significant bits
0x000F, $ Compatible I/O type mask
"Input Assembly 2",
6, "20 04 24 02 30 03", $ Connection Path Size/Path
"Status, Except, Press"; $ Help String
Input2 = 3, $ bytes to be transfered
0, $ significant bits
0x000F, $ Compatible I/O type mask
"Input Assembly 3",
6, "20 04 24 03 30 03", $ Connection Path Size/Path
"Status, Except, Press, TripPoint"; $ Help String
Output1 = 1, $ bytes to be transfered
0, $ significant bits
0x000F, $ Compatible I/O type mask
"Output Assembly 1",
6, "20 04 24 01 30 03", $ Connection Path Size/Path
"HV ON/OFF _ Control"; $ Help String
[ParamClass]
MaxInst=7;
Descriptor=0;
CfgAssembly=0;
[Params]
$ SENSOR PRESSURE OBJECT
$ ****************************************************************************
$ * Parameter Instance #1: Sensor State
$ ****************************************************************************
Param1=
0, $ parameter value slot
6, "20 67 24 01 30 03", $ link size and path
0x0032, $ descriptor (RO, Mon, Enum)
0xC1, 1, $ BOOL, 1 bytes
"Sensor State", $ parameter name
"", $ units string
"Gauge ON == Normal Operation ",
0, 0x1, 0, $ min, max, default
1, 1, 1, 0, $ mult, div, base, offset scaling
0, 0, 0, 0, 0 ; $ scaling links and precision
$ ****************************************************************************
$ * Parameter Instance #2: HV ON/OFF SOURCE
$ ****************************************************************************
Param2=
0, $ parameter value slot
6, "20 67 24 01 30 65", $ link size and path
0x0022, $ descriptor (RO, Mon, Enum)
0xC1, 1, $ BOOL, 1 bytes
"HV ON/OFF Source", $ parameter name
"", $ units string
"You can switch on the high voltage by DeviceNet or an analog input ",
0, 0x1, 0, $ min, max, default
1, 1, 1, 0, $ mult, div, base, offset scaling
0, 0, 0, 0, 0 ; $ scaling links and precision
$ ****************************************************************************
$ * Parameter Instance #3: HV ON/OFF
$ ****************************************************************************
Param3=
0, $ parameter value slot
6, "20 67 24 01 30 64", $ link size and path
0x0022, $ descriptor (RO, Mon, Enum)
0xC1, 1, $ BOOL, 1 bytes
"HV ON/OFF ", $ parameter name
"", $ units string
" ",
0, 0x1, 0, $ min, max, default
1, 1, 1, 0, $ mult, div, base, offset scaling
0, 0, 0, 0, 0 ; $ scaling links and precision
$ ****************************************************************************
$ * Parameter Instance #4: HV State
$ ****************************************************************************
Param4=
0, $ parameter value slot
6, "20 67 24 01 30 66", $ link size and path
0x0032, $ descriptor (RO, Mon, Enum)
0xC1, 1, $ BOOL, 1 bytes
"HV State", $ parameter name
"", $ units string
" ",
0, 0x1, 0, $ min, max, default
1, 1, 1, 0, $ mult, div, base, offset scaling
0, 0, 0, 0, 0 ; $ scaling links and precision
$ TRANSFORM PRESSURE OBJECT
$ ****************************************************************************
$ * Parameter Instance #5: Pressure Value
$ ****************************************************************************
Param5=
0, $ parameter value slot
6, "20 68 24 01 30 01", $ link size and path
0x0030, $ descriptor (RO, Mon, Enum)
0xCA, 4, $ Real, 1 bytes
"Pressure Value", $ parameter name
"", $ units string
"The pressure value is displayed in the actual unit mbar or Torr",
0.000000001, 0.01, 0.000000001, $ min, max, default
1, 1, 1, 0, $ mult, div, base, offset scaling
0, 0, 0, 0, 4; $ scaling links and precision
$ ****************************************************************************
$ * Parameter Instance #6: Pressure Unit
$ ****************************************************************************
Param6=
0, $ parameter value slot
6, "20 68 24 01 30 03", $ link size and path
0x0022, $ descriptor (Mon, Enum)
0xC6, 1, $ USINT, 1 bytes
"Pressure Unit", $ parameter name
"", $ units string
"mbar , Torr , Pascal",
0,2,0, $ min, max, default
1, 1, 1, 0, $ mult, div, base, offset scaling
0, 0, 0, 0, 0 ; $ scaling links and precision
$ ANALOG OUTPUT POINT
$ ****************************************************************************
$ * Parameter Instance #7: Analog Output Mode
$ ****************************************************************************
Param7=
0, $ parameter value slot
6, "20 6A 24 01 30 65", $ link size and path
0x0032, $ descriptor (Mon, Enum)
0xC6, 1, $ USINT, 1 bytes
"Analog Output Mode", $ parameter name
"", $ units string
"Log: Ua=(log(p/mbar)*1.33 +12.66 " ,
0, 0, 0, $ min, max, default
1, 1, 1, 0, $ mult, div, base, offset scaling
0, 0, 0, 0, 0 ; $ scaling links and precision
[EnumPar]
$ ****************************************************************************
$ * Parameter Instance #1: Sensor State
$ ****************************************************************************
Param1=
"FAIL",
"ON";
$ ****************************************************************************
$ * Parameter Instance #2: HV ON/OFF Source
$ ****************************************************************************
Param2=
"Analog Input",
"DeviceNet";
$ ****************************************************************************
$ * Parameter Instance #3: HV ON/OFF
$ ****************************************************************************
Param3=
"HV OFF",
"HV ON";
$ ****************************************************************************
$ * Parameter Instance #4: HV State
$ ****************************************************************************
Param4=
"OFF",
"ON";
$ ****************************************************************************
$ * Parameter Instance #6: Pressure Unit
$ ****************************************************************************
Param6=
"mbar",
"torr",
"Pascal";
$ ****************************************************************************
$ * Parameter Instance #7: Analog Output Mode
$ ****************************************************************************
Param7=
"log";
[Groups]
Group1 = "SPO", 4, 1, 2, 3, 4;
Group2 = "TPO", 2, 5, 6;
Group3 = "AOP" , 1, 7;