$ Electronic Data Sheet for the PEG100-SD
$ 
$

[File]
     DescText    = " Leybold Vakuum PEG100-D EDS File ";
     CreateDate  = 08-08-97;
     CreateTime  = 12:00:00;
     ModDate     = 01-20-2005;
     ModTime     = 12:00:00;
     Revision    = 1.02;
[Device]
     VendCode    = 144;                                $ Vendor Code
     VendName    = "Leybold Vakuum";
     ProdType    = 0;                                  $ Product Type
     ProdTypeStr = "Generic";
     ProdCode    = 3;                                  $ Product Code
     MajRev      = 1;                                  $ Major Rev
     MinRev      = 0;                                  $ Minor Rev
     ProdName    = "PEG100-D";
     Catalog     = "351-003";

[IO_Info]
     Default     = 0x000F;				$ Poll, BitStrobe, COS, Cyclic
     
     PollInfo    = 0x000F, 
     		   1, 					$ Default: Producing 2
     		   1;					$ Default: Consuming 1

     StrobeInfo  = 0x000F, 
     		   1, 					$ Default: Producing 2
     		   1;					$ Default: Consuming 1

     COSInfo     = 0x000F, 
     		   1,					$ Default: Producing 2 
     		   1;					$ Default: Consuming 1

     CyclicInfo  = 0x000F, 
       		   1,					$ Default: Producing 2 
     		   1;					$ Default: Consuming 1
     		   
$ Input Assemblies

     
     Input1      = 6,                                  $ bytes to be transfered
                   0,                                  $ significant bits
                   0x000F,                             $ Compatible I/O type mask
                   "Input Assembly 2",
                   6, "20 04 24 02 30 03",             $ Connection Path Size/Path
                   "Status, Except, Press";            $ Help String

     Input2      = 3,                                 $ bytes to be transfered
                   0,                                  $ significant bits
                   0x000F,                             $ Compatible I/O type mask
                   "Input Assembly 3",
                   6, "20 04 24 03 30 03",             $ Connection Path Size/Path
                   "Status, Except, Press, TripPoint"; $ Help String
                   
                   

     Output1      = 1,                                  $ bytes to be transfered
                    0,                                  $ significant bits
                    0x000F,                             $ Compatible I/O type mask
                    "Output Assembly 1",
                    6, "20 04 24 01 30 03",             $ Connection Path Size/Path
                    "HV ON/OFF _ Control";     	        $ Help String
                    
                      

[ParamClass]
	MaxInst=7;
	Descriptor=0;
	CfgAssembly=0;

[Params]

$ SENSOR PRESSURE OBJECT

$ ****************************************************************************
$ * Parameter Instance #1:  Sensor State
$ ****************************************************************************
        Param1=
                0,                      $ parameter value slot
                6, "20 67 24 01 30 03", $ link size and path
                0x0032,                 $ descriptor (RO, Mon, Enum)
                0xC1, 1,                   $ BOOL, 1 bytes
                "Sensor State",         $ parameter name
                "",                     $ units string
                "Gauge ON == Normal Operation ",
                0, 0x1, 0,              $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision



$ ****************************************************************************
$ * Parameter Instance #2:  HV ON/OFF SOURCE
$ ****************************************************************************
        Param2=
                0,                      $ parameter value slot
                6, "20 67 24 01 30 65", $ link size and path
                0x0022,                 $ descriptor (RO, Mon, Enum)
                0xC1, 1,                   $ BOOL, 1 bytes
                "HV ON/OFF Source",     $ parameter name
                "",                     $ units string
                "You can switch on the high voltage by DeviceNet or an analog input ",
                0, 0x1, 0,              $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision
                
$ ****************************************************************************
$ * Parameter Instance #3:  HV ON/OFF
$ ****************************************************************************
        Param3=
                0,                      $ parameter value slot
                6, "20 67 24 01 30 64", $ link size and path
                0x0022,                 $ descriptor (RO, Mon, Enum)
                0xC1, 1,                   $ BOOL, 1 bytes
                "HV ON/OFF   ",         $ parameter name
                "",                     $ units string
                " ",
                0, 0x1, 0,              $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision
                
                
$ ****************************************************************************
$ * Parameter Instance #4:  HV State
$ ****************************************************************************
        Param4=
                0,                      $ parameter value slot
                6, "20 67 24 01 30 66", $ link size and path
                0x0032,                 $ descriptor (RO, Mon, Enum)
                0xC1, 1,                   $ BOOL, 1 bytes
                "HV State",         $ parameter name
                "",                     $ units string
                " ",
                0, 0x1, 0,              $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision



$ TRANSFORM PRESSURE OBJECT

$ ****************************************************************************
$ * Parameter Instance #5:  Pressure Value
$ ****************************************************************************
        Param5=
                0,                      $ parameter value slot
                6, "20 68 24 01 30 01", $ link size and path
                0x0030,                 $ descriptor (RO, Mon, Enum)
                0xCA, 4,                  $ Real, 1 bytes
                "Pressure Value",       $ parameter name
                "",                     $ units string
                "The pressure value is displayed in the actual unit mbar or Torr",
                0.000000001, 0.01, 0.000000001,   $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 4;          $ scaling links and precision


$ ****************************************************************************
$ * Parameter Instance #6:  Pressure Unit
$ ****************************************************************************
        Param6=
                0,                      $ parameter value slot
                6, "20 68 24 01 30 03", $ link size and path
                0x0022,                 $ descriptor (Mon, Enum)
                0xC6, 1,                   $ USINT, 1 bytes
                "Pressure Unit",        $ parameter name
                "",                     $ units string
                "mbar , Torr , Pascal",
                0,2,0,                  $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision



$ ANALOG OUTPUT POINT

$ ****************************************************************************
$ * Parameter Instance #7:  Analog Output Mode
$ ****************************************************************************
        Param7=
                0,                      $ parameter value slot
                6, "20 6A 24 01 30 65", $ link size and path
                0x0032,                 $ descriptor (Mon, Enum)
                0xC6, 1,                  $ USINT, 1 bytes
                "Analog Output Mode",   $ parameter name
                "",                     $ units string
                "Log: Ua=(log(p/mbar)*1.33 +12.66 "   ,
                0, 0, 0,                $ min, max, default
                1, 1, 1, 0,             $ mult, div, base, offset scaling
                0, 0, 0, 0, 0 ;         $ scaling links and precision




[EnumPar]
$ ****************************************************************************
$ * Parameter Instance #1:  Sensor State
$ ****************************************************************************
        Param1=
                "FAIL",
                "ON";


$ ****************************************************************************
$ * Parameter Instance #2:  HV ON/OFF Source
$ ****************************************************************************
        Param2=
                "Analog Input",
                "DeviceNet";
                
$ ****************************************************************************
$ * Parameter Instance #3:  HV ON/OFF
$ ****************************************************************************
        Param3=
                "HV OFF",
                "HV ON";                

$ ****************************************************************************
$ * Parameter Instance #4:  HV State
$ ****************************************************************************
        Param4=
                "OFF",
                "ON";


$ ****************************************************************************
$ * Parameter Instance #6:  Pressure Unit
$ ****************************************************************************
        Param6=
                "mbar",
                "torr",
                "Pascal";


$ ****************************************************************************
$ * Parameter Instance #7:  Analog Output Mode
$ ****************************************************************************
        Param7=
                "log";



[Groups]
      Group1 = "SPO", 4, 1, 2, 3, 4;
      Group2 = "TPO",  2, 5, 6;
      Group3 = "AOP" , 1, 7;