$ $ Electronic Data Sheet for the TTR211S-D $ Leybold Vakuum GmbH $ [File] DescText = " Leybold Vakuum TTR21XS-D EDS File - TTR2"; CreateDate = 08-08-97; CreateTime = 12:00:00; ModDate = 10-29-2003; ModTime = 12:00:00; Revision = 1.02; [Device] VendCode = 144; $ Vendor Code VendName = "Leybold Vakuum"; ProdType = 0; $ Product Type ProdTypeStr = "Generic"; ProdCode = 2; $ Product Code MajRev = 1; $ Major Rev MinRev = 0; $ Minor Rev ProdName = "TTR211S-D"; Catalog = "89651"; [IO_Info] Default = 0x0001; $ Poll, BitStrobe, COS PollInfo = 0x0007, 1, $ Default: Producing 3 1; $ Default: Consuming 1 StrobeInfo = 0x0007, 3, $ Default: Producing 5 1; $ Default: Consuming 1 COSInfo = 0X0007, 1, $ Default: Producing 3 1; $ Default: Consuming 1 $ Input Assemblies Input1 = 6, $ bytes to be transfered 0, $ significant bits 0x0007, $ Compatible I/O type mask "Input Assembly 3", 6, "20 04 24 03 30 03", $ Connection Path Size/Path "Status, Except, Press"; $ Help String Input2 = 14, $ bytes to be transfered 0, $ significant bits 0x0007, $ Compatible I/O type mask "Input Assembly 4", 6, "20 04 24 04 30 03", $ Connection Path Size/Path "Status, Except, Press, TripPoint"; $ Help String Input3 = 4, $ bytes to be transfered 0, $ significant bits 0x0007, $ Compatible I/O type mask "Input Assembly 5", 6, "20 04 24 05 30 03", $ Connection Path Size/Path "Pressure"; $ Help String Input4 = 1, $ bytes to be transfered 0, $ significant bits 0x0007, $ Compatible I/O type mask "Input Assembly 6", 6, "20 04 24 06 30 03", $ Connection Path Size/Path "Exception"; $ Help String Output1 = 1, $ bytes to be transfered 0, $ significant bits 0x0007, $ Compatible I/O type mask "Output Assembly 1", 6, "20 04 24 01 30 03", $ Connection Path Size/Path "Trip Source"; $ Help String Output2 = 9, $ bytes to be transfered 0, $ significant bits 0x0007, $ Compatible I/O type mask "Output Assembly 2", 6, "20 04 24 02 30 03", $ Connection Path Size/Path "Trip Source, Trip Point"; $ Help String [ParamClass] MaxInst=11; Descriptor=0; CfgAssembly=0; [Params] $ SENSOR PRESSURE OBJECT $ **************************************************************************** $ * Parameter Instance #1: Sensor State $ **************************************************************************** Param1= 0, $ parameter value slot 6, "20 67 24 01 30 03", $ link size and path 0x0032, $ descriptor (RO, Mon, Enum) 0xC1, 1, $ BOOL, 1 bytes "Sensor State", $ parameter name "", $ units string "Gauge ON == Normal Operation ", 0, 0x1, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ TRANSFORM PRESSURE OBJECT $ **************************************************************************** $ * Parameter Instance #2: Pressure Value $ **************************************************************************** Param2= 0, $ parameter value slot 6, "20 68 24 01 30 01", $ link size and path 0x0030, $ descriptor (RO, Mon, Enum) 0xca, 4, $ Real, 1 bytes "Pressure Value", $ parameter name "", $ units string "The pressure value is displayed in the actual unit mbar or Torr", 0.0005, 1000, 0.0005, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 4; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #3: Pressure Unit $ **************************************************************************** Param3= 0, $ parameter value slot 6, "20 68 24 01 30 03", $ link size and path 0x0022, $ descriptor (Mon, Enum) 0xc6, 1, $ USINT, 1 bytes "Pressure Unit", $ parameter name "", $ units string "mbar , Torr , Pascal", 0,2,0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ DISCRETE OUTPUT POINT $ **************************************************************************** $ * Parameter Instance #4: TP State $ **************************************************************************** Param4= 0, $ parameter value slot 6, "20 69 24 01 30 03", $ link size and path 0x0032, $ descriptor (Mon, Enum) 0xC1, 1, $ BOOL, 1 bytes "Trip Point State", $ parameter name "", $ units string "0 relais deactivated, 1 relais activated ", 0, 0x1, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #5: TP $ **************************************************************************** Param5= 0, $ parameter value slot 6, "20 69 24 01 30 64", $ link size and path 0x0020, $ descriptor (RO, Mon, Enum) 0xca, 4, $ Real, 1 bytes "Trip Point", $ parameter name "", $ units string "Only active if Trip Point Control Source == DeviceNet", 0.0005, 1000, 0.0005, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 4; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #6: TP Hysteresis $ **************************************************************************** Param6= 0, $ parameter value slot 6, "20 69 24 01 30 66", $ link size and path 0x0020, $ descriptor ( Mon, Enum) 0xca, 4, $ Real, 1 bytes "Trip Point Hysteresis", $ parameter name "%", $ units string "Hysteresis in Percent", 0.1, 100, 0.1, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 4; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #7: TP Upper Value $ **************************************************************************** Param7= 0, $ parameter value slot 6, "20 69 24 01 30 67", $ link size and path 0x0020, $ descriptor (RO, Mon, Enum) 0xca, 4, $ Real, 1 bytes "Trip Point Upper Value", $ parameter name "", $ units string "Only active if Trip Point Control Source == DeviceNet", 0.0005, 1000, 0.0005 , $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 4; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #8: TP Lower Value $ **************************************************************************** Param8= 0, $ parameter value slot 6, "20 69 24 01 30 68", $ link size and path 0x0020, $ descriptor ( Mon, Enum) 0xca, 4, $ Real, 1 bytes "Trip Point Lower Value", $ parameter name "", $ units string "Only active if Trip Point Control Source == DeviceNet", 0.0005, 1000, 0.0005 , $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 4; $ scaling links and precision $ **************************************************************************** $ * Parameter Instance #9: TP Control Source $ **************************************************************************** Param9= 0, $ parameter value slot 6, "20 69 24 01 30 69", $ link size and path 0x0022, $ descriptor (Mon, Enum) 0xC1, 1, $ BOOL, 1 bytes "Trip Point Control Source", $ parameter name "", $ units string "You can define whether the trip point is installed by DeviceNet or by the potentiometer of the ITR100-D", 0, 0x1, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision $ ANALOG OUTPUT POINT $ **************************************************************************** $ * Parameter Instance #10: Analog Output Mode $ **************************************************************************** Param10= 0, $ parameter value slot 6, "20 70 24 01 30 65", $ link size and path 0x0032, $ descriptor (Mon, Enum) 0xc6, 1, $ USINT, 1 bytes "Analog Output Mode", $ parameter name "", $ units string "Log: Ua=(log(p/mbar)*1.286 +6.143 " , 0, 0, 0, $ min, max, default 1, 1, 1, 0, $ mult, div, base, offset scaling 0, 0, 0, 0, 0 ; $ scaling links and precision [Groups] $ Group1="SPO",1; $ Group2="TPO",2,3; $ Group3="DOP",4,5,6,7,8,9; $ Group4="AOP",10; [EnumPar] $ **************************************************************************** $ * Parameter Instance #1: Sensor State $ **************************************************************************** Param1= "FAIL", "ON"; $ **************************************************************************** $ * Parameter Instance #3: Pressure Unit $ **************************************************************************** Param3= "mbar", "torr", "Pascal"; $ **************************************************************************** $ * Parameter Instance #4: TP State $ **************************************************************************** Param4= "OFF", "ON"; $ **************************************************************************** $ * Parameter Instance #9: TP Control Source $ **************************************************************************** Param9= "Potentiometer", "DeviceNet"; $ **************************************************************************** $ * Parameter Instance #10: Analog Output Mode $ **************************************************************************** Param10= "log";